OES Co., Ltd. is now uniquely positioned and evaluated by our catalytic ammonia eliminating technology in Chemical and Electronics Industries.

TITERIXCatalyst for Ammonia Destruction

Characteristics

Ammonia gas treatment Catalyst

ReNOx catalyst(TITERIX) is completely different from well known catalysts such as precious metal monolith, pellets etc for every points of view: Structure, Active Components and Superiorities of Effect in actual use etc.

ReNOx catalyst is easy for handling, having Superior Strength and Durability for thermal and mechanical shocks.

Nitrogen compounds frequently used in processing Electronics Parts Production, such as Ammonia, badly smelling Amines etc. should not be exhausted both gaseous nor aqueous phase as itself. ReNOx catalyst are especially suitable for make it harmless as N2, processing with high efficiency and energy saving.
No conventional technologies or systems could be competed for ReNOx.


Catalytic Burning Method : Equation of Chemical Reaction

Catalytic Burning Method

Ammonia gas burning (reaction with oxygen)
    4NH3+3O2

Finally, dissociated to Nitrogen(N2) and water vapor,exhaust to air.
    2N2+6H2O

*NOx, as it is one of environmental toxic matters,
  caused pollution of acid rain, overnutrition for forest and river.
*N2, a component over 70% of air, is not toxic at all.


Catalyst Performance

TITELIX
SV.value(*1) 16,000h-1
Reaction temperature 350℃
Maximum operating temperature
(Thermal endurance)
550℃
Maximum operating concentration
(Normal processing concentration)
18,000ppm
(15,000ppm)
Deodorizing ability >>Reference : ReNOx
Carcinogen None

*1 ; Space Verocity
Treated gas volume passing through the unit catalst space at 0℃,1atm. per hour.(unit:1/hour)


*Comparison : Ammonia Gas about7kg/Hr

Items TITERIX Catalyst equipped unit(ReNOx) Conventional processing machine
Outer air 10Nm3/min. 20Nm3/min.
Destructive heat emission 165 rise 87 rise
Necessary energy of heating 1kw 21kw


*Data shown as actually observed,not for insurance.